Mining Cable

Applications

For use with magnet cranes and other mobile or portable electrical equipment. Can be used on equipment with reeling devices.
Part No
VOLTAGE
ITEM
AWG
COND
COND STRAND
JACKET COLORS
NOM INSUL (IN)
NOM OD (IN)
AMPACITY
WGT/M’
5MC-8-2
2kv
Magnet Crane
8
2
133
0.06
0.83
74
369
5MC-6-2
2kv
Magnet Crane
6
2
133
0.06
0.96
99
518
5MC-4-2
2kv
Magnet Crane
4
2
133
0.06
1.08
130
715
5MC-2-2
2kv
Magnet Crane
2
2
259
0.06
1.28
174
1045
5MC-1/0-2
2kv
Magnet Crane
1/0
2
266
0.08
1.56
234
1464
5MC-2/0-2
2kv
Magnet Crane
2/0
2
342
0.08
1.66
271
1788
5MC-4/0-2
2kv
Magnet Crane
4/0
2
532
0.08
1.973
361
2530
5MC-250-2
2kv
Magnet Crane
250
2
627
0.095
2.1
402
2664
5MC-350-2
2kv
Magnet Crane
350
2
888
0.095
2.36
495
3854
5MC-500-2
2kv
Magnet Crane
500
2
1221
0.095
2.7
613
5191

Specifications

  • Voltage: 600/2000 Volts.
  • Temperature: 90°C.
  • Conductor: Rope-stranded tinned copper.
  • Insulation: Ethylene propylene rubber (EPR).
  • Standards: Meets the requirements of ICEA S-68-516. Accepted by MSHA and marked with the manufacturer’s P number.
  • Assembly: Two conductors cabled with fillers, over-wrapped with reinforced binder, separated where applicable.

Applications

For use as flexible power lead with any portable or mobile equipment such as pumps, welders, mining machines and mine conveyor equipment.
Part No
VOLTAGE
ITEM
AWG
COND
POWER COND STRAND
GROUNDING COND SIZE
JACKET COLORS
NOM INSUL (IN)
NOM OD (IN)
AMPACITY
WGT/M’
5G-8-4
2kv
Type G
8
4
133
4 #12
0.06
1.045
52
635
5G-6-4
2kv
Type G
6
4
259
4 #12
0.06
1.1
72
910
5G-4-4
2kv
Type G
4
4
259
4 #10
0.06
1.27
93
1378
5G-2-4
2kv
Type G
2
4
259
4 #9
0.06
1.48
122
1914
5G-1-4
2kv
Type G
1
4
259
4 #8
0.08
1.68
143
2311
5G-1/0-4
2kv
Type G
1/0
4
259
4 #7
0.08
1.79
165
2810
5G-2/0-4
2kv
Type G
2/0
4
259
4 #6
0.08
1.93
192
3253
5G-3/0-4
2kv
Type G
3/0
4
259
4 #5
0.08
2.07
221
4099
5G-4/0-4
2kv
Type G
4/0
4
259
4 #4
0.08
2.26
255
4925
5G-250-4
2kv
Type G
250
4
427
4 #3
0.095
2.66
280
6060
5G-350-4
2kv
Type G
350
4
427
4 #1
0.095
2.98
335
8126
5G-500-4
2kv
Type G
500
4
427
4 #1/0
0.095
3.4
395
10758

Specifications

  • Voltage: 600/2000 Volts.
  • Temperature: 90°C.
  • Conductor: Rope-stranded copper.
  • Insulation: Ethylene propylene rubber (EPR).
  • Standards: Meets the requirements of ICEA S-75-381 (NEMA WC58). Accepted by MSHA and marked with the manufacturer’s P number.
  • Assembly: Conductors and ground wires cabled with fillers as necessary.

Applications

For use as flexible power lead with any portable or mobile equipment such as pumps, welders, mining machines and mine conveyor equipment.
Part No
VOLTAGE
ITEM
AWG
COND
POWER COND STRAND
GROUNDING COND SIZE
GROUND CHECK SIZE
JACKET COLORS
NOM INSUL (IN)
NOM OD (IN)
AMPACITY
WGT/M’
5GGC-8-3
2kv
Type G-GC
8
3
133
2 #10
#10
0.06
0.975
65
700
5GGC-6-3
2kv
Type G-GC
6
3
259
2 #10
#10
0.06
1.05
87
813
5GGC-4-3
2kv
Type G-GC
4
3
259
2 #8
#10
0.06
1.19
114
1117
5GGC-2-3
2kv
Type G-GC
2
3
259
2 #7
#10
0.06
1.33
152
1565
5GGC-1-3
2kv
Type G-GC
1
3
259
2 #6
#8
0.08
1.51
177
1921
5GGC-1/0-3
2kv
Type G-GC
1/0
3
259
2 #5
#8
0.08
1.63
205
2520
5GGC-2/0-3
2kv
Type G-GC
2/0
3
259
2 #4
#8
0.08
1.73
237
2768
5GGC-3/0-3
2kv
Type G-GC
3/0
3
259
2 #3
#8
0.08
1.86
274
3518
5GGC-4/0-3
2kv
Type G-GC
4/0
3
259
2 #2
#8
0.08
2.01
316
4195
5GGC-250-3
2kv
Type G-GC
250
3
427
2 #1
#6
0.095
2.36
352
5146
5GGC-350-3
2kv
Type G-GC
350
3
427
2 #1/0
#6
0.095
2.67
433
6799
5GGC-500-3
2kv
Type G-GC
500
3
427
2 #3/0
#6
0.095
3.03
536
9214

Specifications

  • Voltage: 600/2000 Volts.
  • Temperature: 90°C.
  • Conductor: Rope-stranded copper.
  • Insulation: Ethylene propylene rubber (EPR).
  • Standards: Meets the requirements of ICEA S-75-381 (NEMA WC58). Accepted by MSHA and marked with the manufacturer’s P number.
  • Assembly: Conductors and ground wires cabled with fillers as necessary.

Applications

For use in mining machines, loaders and welders; as motor leads; in temporary power installations; in utility maintenance; and in other mobile equipment.
Part No
VOLTAGE
ITEM
AWG
COND
COND STRAND
JACKET COLORS
NOM INSUL (IN)
NOM OD (IN)
AMPACITY
WGT/M’
5W-8-2
2kv
Type W
8
2
133
0.06
0.78
74
365
5W-6-2
2kv
Type W
6
2
259
0.06
0.91
99
515
5W-4-2
2kv
Type W
4
2
259
0.06
1.04
130
730
5W-2-2
2kv
Type W
2
2
259
0.08
1.22
174
1000
5W-1-2
2kv
Type W
1
2
259
0.08
1.44
202
1490
5W-1/0-2
2kv
Type W
1/0
2
259
0.08
1.52
234
1710
5W-2/0-2
2kv
Type W
2/0
2
259
0.08
1.65
271
1880
5W-3/0-2
2kv
Type W
3/0
2
259
0.08
1.77
313
2420
5W-4/0-2
2kv
Type W
4/0
2
259
0.08
1.92
361
2940
5W-8-3
2kv
Type W
8
3
133
0.06
0.925
74
525
5W-6-3
2kv
Type W
6
3
259
0.06
0.995
99
660
5W-4-3
2kv
Type W
4
3
259
0.06
1.125
130
900
5W-2-3
2kv
Type W
2
3
259
0.08
1.285
174
1300
5W-1-3
2kv
Type W
1
3
259
0.08
1.49
202
1600
5W-1/0-3
2kv
Type W
1/0
3
259
0.08
1.65
234
2280
5W-2/0-3
2kv
Type W
2/0
3
259
0.08
1.75
271
2680
5W-3/0-3
2kv
Type W
3/0
3
259
0.08
1.89
313
3220
5W-4/0-3
2kv
Type W
4/0
3
259
0.095
2.04
361
3900
5W-250-3
2kv
Type W
250
3
627
0.095
2.39
402
5070
5W-350-3
2kv
Type W
350
3
855
0.095
2.68
495
6570
5W-500-3
2kv
Type W
500
3
1235
0.095
3.03
613
8700
5W-8-4
2kv
Type W
8
4
133
0.06
0.985
65
641
5W-6-4
2kv
Type W
6
4
259
0.06
1.09
87
818
5W-4-4
2kv
Type W
4
4
259
0.06
1.22
114
1140
5W-2-4
2kv
Type W
2
4
259
0.08
1.42
152
1630
5W-1-4
2kv
Type W
1
4
259
0.08
1.68
177
1982
5W-1/0-4
2kv
Type W
1/0
4
259
0.08
1.72
205
2393
5W-2/0-4
2kv
Type W
2/0
4
259
0.08
1.93
237
2904
5W-3/0-4
2kv
Type W
3/0
4
259
0.08
2.07
274
3377
5W-4/0-4
2kv
Type W
4/0
4
259
0.08
2.26
316
4264
5W-250-4
2kv
Type W
250
4
608
0.095
2.5
352
5353
5W-350-4
2kv
Type W
350
4
855
0.095
2.7
433
6969
5W-500-4
2kv
Type W
500
4
1221
0.095
2.9
512
9456
5W-8-5
2kv
Type W
8
5
133
0.06
1.05
52
710
5W-6-5
2kv
Type W
6
5
259
0.06
1.205
69
1010
5W-4-5
2kv
Type W
4
5
259
0.06
1.55
91
1400
5W-2-5
2kv
Type W
2
5
259
0.08
1.61
121
2340
5W-1-5
2kv
Type W
1
5
259
0.08
1.88
141
3040
5W-1/0-5
2kv
Type W
1/0
5
259
0.08
2.075
164
3460
5W-2/0-5
2kv
Type W
2/0
5
259
0.08
2.13
189
4180
5W-3/0-5
2kv
Type W
3/0
5
259
0.08
2.26
219
4900
5W-4/0-5
2kv
Type W
4/0
5
259
0.08
2.46
252
5980

Specifications

  • Voltage: 600/2000 Volts.
  • Temperature: 90°C.
  • Conductor: Rope-stranded copper.
  • Insulation: Ethylene propylene rubber (EPR).
  • Standards: Meets the requirements of ICEA S-75-381 (NEMA WC58). Accepted by MSHA and marked with the manufacturer’s P number. UL Listed.
  • Assembly: The specified number of conductors cabled with fillers, over-wrapped with reinforced binder, separator where applicable.